低能量DPL联合舒敏之星治疗面部敏感性皮肤疗效观察与分析
作者:
作者单位:

作者简介:

段娜(1989.9-),女,陕西西安人,硕士,主治医师,主要从事敏感性皮肤的光电治疗工作

通讯作者:

中图分类号:

R751

基金项目:


Clinical Effect of Low Energy DPL Combined with Short Wave Physiotherapy Instrument in the Treatment of Facial Sensitive Skin
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 分析低能量DPL联合短波理疗仪治疗面部敏感性皮肤的效果与安全性。方法 选择2023年 2月-7月就诊于本院的52例面部敏感性皮肤患者作为研究对象,将患者面部左侧作为试验侧,右侧作为 对照侧。对照侧采用短波理疗仪治疗,试验侧在对照侧的基础上联合低能量DPL治疗,比较两侧临床疗 效、皮肤及皮肤屏障状态、美容满意度、不良反应发生率、复发情况。结果 试验侧治疗后总有效率为 76.92%,高于对照侧的57.69%(P <0.05);试验侧治疗后血红色指数、凹陷指数、经表皮失水量均低于 对照侧(P <0.05);试验侧治疗后红斑百分数、角质层含水量均高于对照侧(P <0.05);试验侧美容满 意度为78.85%,高于对照侧的59.62%(P <0.05);两侧治疗过程中及治疗后均未出现不良反应;随访3个 月,患者均未复发。结论 低能量DPL联合短波理疗仪治疗面部敏感性皮肤能够提高临床疗效,可改善皮 肤及皮肤屏障状态,提高患者满意度,可有效预防不良反应发生,降低复发率,值得借鉴。

    Abstract:

    Objective To analyze the efficacy and safety of low energy DPL combined with short wave physiotherapy instrument in the treatment of facial sensitive skin. Methods A total of 52 patients with facial sensitive skin who were treated in our hospital from February to July 2023 were selected as the study subjects. The left side of the patient's face was used as the experimental side, and the right side was used as the control side. The control side was treated with short wave physiotherapy instrument, and the experimental side was treated with low-energy DPL on the basis of the control side. The clinical efficacy, skin and skin barrier status, cosmetic satisfaction, incidence of adverse reactions and recurrence were compared between the two sides. Results The total effective rate of the experimental side after treatment was 76.92%, which was higher than 57.69% of the control side (P <0.05). After treatment, the blood red index, depression index and transepidermal water loss of the experimental side were lower than those of the control side (P <0.05). After treatment, the percentage of erythema and the water content of stratum corneum on the experimental side were higher than those on the control side (P <0.05). The cosmetic satisfaction of the test side was 78.85%, which was higher than 59.62% of the control side (P <0.05). There were no adverse reactions during and after treatment on both sides. The patients were followed up for 3 months, and no recurrence was found. Conclusion Low energy DPL combined with short wave physiotherapy instrument can improve clinical efficacy for patients with facial sensitive skin, improve their skin barrier status, improve patient satisfaction. Meanwhile, it can effectively prevent adverse reactions and reduce recurrence rate, which is worthy of reference.

    参考文献
    相似文献
    引证文献
引用本文

段娜.低能量DPL联合舒敏之星治疗面部敏感性皮肤疗效观察与分析[J].医学美学美容,2024,33(9):43-46.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-05-13
  • 出版日期: